E-1 special utility relays – KEYENCE KV Series User Manual

Page 198

Advertising
background image

Appendices

2-174

Appendices

Appendix E

Devices for KV-10R(W)/T(W) to 80R(W)/T(W),
KV-300

E-1

Special utility relays

Special relays and arithmetic flags

Utility relays for high-speed counter (0)

* Valid with the KV-300 only.

Utility relays for high-speed counter (1)

Relay No.

Function

2000

Undefined

2001

Undefined

2002

Always ON

2003

Always OFF

2004

0.01 s clock pulse (duty cycle: 50%)

2005

0.1 s clock pulse (duty cycle: 50%)

2006

1.0 s clock pulse (duty cycle: 50%)

2007

OFF for first scan time at startup

2008

ON for first scan time at startup

2009

ON when result of arithmetic operation is negative or an overflow is
generated.

2010

ON when result of arithmetic operation is 0.

2011

ON when result of arithmetic operation is positive.

2012

ON when arithmetic operation generates an error.

Relay No.

Function

2100

Internal clock (0.8 µs/1 µs in KV-300) used only for CTH0

2101

Internal clock (6.4 µs/10 µs in KV-300) used only for CTH0

2102

Internal clock (102.4 µs/100 µs in KV-300) used only for CTH0

2103

When comparator CTC0 is ON, clear CTC0 automatically.

1: Yes

0: No.

2104

Direct output to 0500.

1: Disabled 0: Enabled

2105

Turns OFF output to 0500.

1: Yes

0: No

2106

Turns ON output to 0500.

1: Yes

0: No

2107

Reverses (toggles) output to 0500. 1: Yes

0: No

2108

Direct output to 0500.

1: Disabled 0: Enabled

2109

Turns OFF output to 0500.

1: Yes

0: No

2110

Turns ON output to 0500.

1: Yes

0: No

2111

Reverses (toggles) output to 0500. 1: Yes

0: No

*2112

When comparator CTC1 is ON, clears CTC0 automatically.

1: Yes

0: No.

*2113

Uses CTH0 in multiply mode.

1: Yes

0: No

*2114

Selects multiply mode for CTH0.

1: x4

0: x2

*2115

Enables external reset of CTH0.

1: Yes

0: No

Level of
direct output
to 0500 by
comparator
CTC0
(either one
is ON)

Level of
direct output
to 0500 by
comparator
CTC1
(either one
is ON)

Relay No.

Function

2200

Internal clock (0.8 µs/1 µs in KV-300) used only for CTH1

2201

Internal clock (6.4 µs/10 µs in KV-300) used only for CTH1

2202

Internal clock (102.4 µs/100 µs in KV-300) used only for CTH1

2203

When comparator CTC2 is ON, clears CTC1 automatically.

1: Yes 0: No

2204

Direct output to 0501 by comparator CTC2.

1: Yes 0: No

2205

Level of direct output to 0501 by comparator CTC2.

1: ON 0: OFF

KVSKA Appendix.P65

08.3.11, 11:26 AM

174

Advertising