KEYENCE KV Series User Manual

Page 201

Advertising
background image

Appendices

2-177

1

Appendices

DM9500

Slot number in which the error occurred

DM9501

Channel number within slot in which the error occurred

DM9507 to DM9517

I/O module connection information map

Set item

Allowable setting range

DM9407

Preset value error code

11 to 7

DM9408

X-axis startup frequency (Hz)

153 to 50000

DM9409

X-axis operation frequency (Hz)

153 to 50000

DM9410

X-axis acceleration/deceleration time (ms)

0 to 4096

DM9411

X-axis output pulses (higher-order 16 bits)

0 to 65535

DM9412

X-axis output pulses (lower-order 16 bits)

2 to 65535

DM9413

Y-axis startup frequency (Hz)

153 to 50000

DM9414

Y-axis operation frequency (Hz)

153 to 50000

DM9415

Y-axis acceleration/deceleration time (ms)

0 to 4096

DM9416

Y-axis output pulses (higher-order 16 bits)

0 to 65535

DM9417

Y-axis output pulses (lower-order 16 bits)

2 to 65535

DM9600

First DM number that stores ASCII code

DM9601

First DM number to which converted BIN value is written

DM9602

First DM number to which converted ASCII code is written

DM9603

First DM number that stores BIN value

DM1485 X #65536 + DM1484

(output pulses)

DM1481
(operation)

Frequency (Hz)

DM1480
(startup)

0

DM1482

DM1482

Time (ms)

(acceleration time)

(deceleration time)

I/O module error information (valid in the KV-300 only)

Data memory for motor drive (valid in the KV-300 only)

Data memory to convert ASCII character string into BIN value (32 bits)

Data memory to convert BIN value (32 bits) into ASCII character string

KVSKA Appendix.P65

08.3.11, 11:26 AM

177