KEYENCE KV Series User Manual

Page 197

Advertising
background image

Appendices

2-173

1

Appendices

DM1485 X #65536 + DM1484

(output pulses)

DM1481
(operation)

Frequency (Hz)

DM1480
(startup)

0

DM1482

DM1482

Time (ms)

(acceleration time)

(deceleration time)

Setting contents

Setting range

DM1480

Ramp up-and-down control startup frequency (Hz)

200 to 50000

DM1481

Ramp up-and-down control operating frequency (Hz)

200 to 50000
(value larger than
startup frequency)

DM1482

Ramp up-and-down control acceleration/deceleration

0 to 4000

time (ms)

DM1484

Number of output pulses (lower 16 bits)

0 to 65535
(2 or more when
DM1485 is 0)

DM1485

Number of output pulses (upper 16 bits)

0 to 65535

DM1486

Set value error code

When an error
occurs, a
corresponding error
code 11 to 17 is
stored.

Data memories for motor drive

KVSKA Appendix.P65

08.3.11, 11:26 AM

173

Advertising