Threshold manager, Temperatures tab, 20 threshold manager – Doremi IMS1000 User Manual

Page 181

Advertising
background image

IMS.OM.002949.DRM

Page 181 of 320

Version 1.7

Doremi Labs

12.20 Threshold Manager

The Threshold Manager allows the user to view and adjust the threshold values for temperature,
voltage, fans, and certain errors.

To access the Threshold Manager, go to Administration

→ Control Panel → Threshold

Manager.

When opened, the default tab is the Help tab. This tab offers an explanation of the application
(Figure 215).

Figure 215: Help Tab

Note: Although the user is able to change the threshold values, it is recommended that the user
leave the default values.

Each tab lists the high and low threshold as well as the hysteresis value, which is optional. The
default hysteresis value is 0 but this can be changed.

The hysteresis value is the plus or minus tolerance value, meaning that an alert will appear
when the threshold high or low is reached and will not appear again until the hysteresis value is
reached. This is to prevent multiple alerts from appearing if the value continues to remain above
the threshold values. Once the hysteresis value is reached, an alert will appear.

12.20.1

Temperatures Tab

The Temperature tab lists the high and low threshold values for different components of the
server, in degrees Celsius. Hovering over the component will give a brief explanation of that
component.

Help

Tab