15.2 Rebuild Progress

The Storage tab will allow you to view the rebuild progress in Storage Details after you have
replaced and inserted a new disk (Figure 335).

Note: When the server is rebuilding a RAID, an orange icon will appear to indicate that the
RAID is being rebuilt.

Figure 335: Rebuild Status

15.2.1 Managing a Drive

Support for this feature is forthcoming. Presently, the only way to disable a drive is to physically
remove it from the RAID.

15.3 Rebuilding a RAID

When 2 or more

drives have been installed, you must build the RAID. Go to Monitoring →

Diagnostics → Storage tab to see the status of the RAID. If you need to build, the RAID status
will be degraded.

To build the RAID, go to the Reset All Drives tab in the Storage tab (Figure 335).

● Click the Reset All Drives button (Figure 335).
● The user will receive a warning and will be asked to confirm the procedure (Figure 336).
● Click Continue to continue or Cancel to cancel the operation.

Rebuild

Progress

Reset

All

Drives

Button

Advertising