Local end distant end – Comtech EF Data CDM-570 User Manual

Page 198

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 12

Clocking Modes

MN/CDM570L.IOM

10–8

USER

EQUIPMENT

Notes:

1) The EIA-530 / v.35 interface can
operate at any data rate, with
1 bps resolution

2) Tx and Rx bit rates can be
asymmetrical

3) Works with multiple distant end
modems (STAR networks)

LOCAL END

DISTANT END

G.703 input (T1/E1)

from high stability

network source

EIA-53

0 / v.3

5

Int

e

rf

ac

e

SD

RT

RD

TT

ST

CDM-570/570L

Rx

Buffer

Clock
Synth

Core

Demod

Mod

SD

TT

G.

7

0

3 Po

rt

2048 or

1544 KHz

O

Tx timing mode:
Internal clock locked to G.703

Rx:
Buffer enabled, clocked from ST

USER

EQUIPMENT

G.703 output (T1/E1)

(all ones pattern)

EIA

-53

0 /

v.35

Interface

RD

TT

ST

RT

CDM-570/570L

Clock
Synth

Core

Demod

G.703

P

o

rt

2048 or

1544 KHz

O

Timing mode:
Usually loop timing (or Rx-Sat)
Rx buffer disabled

SD

END RESULT:
The G.703 signal at is perfectly reproduced
at , regardless of the link data rate

A

B

B

A

Any desired
bit rate




































Figure 10-3. G.703 Clock Extension Mode 1