2 48 v dc units – cdmr-570l unit only, 3 ground connector – Comtech EF Data CDM-570 User Manual

Page 76

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 12

Rear Panel Connectors and Pinouts

MN/CDM570L.IOM

3–12

3.5.2.2 48 V DC Units – CDMR-570L Unit Only

This optional connection supplies the 48V Direct Current (DC)
power to the CDMR-570L modem.




Note the following:

DC Power Specifications

Input Power

48 watts typical, 55 watts maximum

Input Voltage

48 volts DC nominal (43 volts to 60 volts)

Connector Type

Terminal Block

Fuse Protection

Use one (1X) Slow-Blow TR5 type fuse – fuse is contained within a screw-in receptacle
located to the left of the terminal block:

• Use a TR5 6.3A fuse for all CDMR-570L units ( with or without BUC)

3.5.3 Ground Connector

PROPER GROUNDING PROTECTION REQUIRED: The installation instructions
require that the integrity of the protective earth must be ensured and that the
equipment shall be connected to the protective earth connection at all times.
Therefore, it is imperative during installation, configuration, and operation to
ensure that the unit has been properly grounded using the ground stud provided
on the rear panel of the unit.

A #10-32 stud provided on the rear panel of the modem is used for connecting a
common chassis ground among equipment.

Note: The AC power connector provides the safety ground.