Comtech EF Data CDM-570 User Manual

Page 375

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 12

Appendix D

MN/CDM570L.IOM

D–25

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

T1 Line
Build-Out

LBO= 1

byte,

value of 0 thru 4

Command or Query.
Valid only for T1 interface, where
0 = 0-133 feet
1 = 133-266 feet
2 = 266-399 feet
3 = 399-533 feet
4 = 533-655 feet
Example: LBO=2
(In all other modes other thanT1, this is a don’t care.)

LBO=

LBO?
LBO *
LBO #

LBO?

LBO=x
(see Description of
Arguments)

Local/Remote
Status

LRS= 1

byte,

value of 0, 1 or 3

Command or Query.
Local/Remote status, where:
0=Local
1=Serial Remote
3 = Ethernet Remote
Example: LRS=1 (Serial Remote)

LRS=

LRS?
LRS*
LRS#
LRS+

LRS?

LRS=x
(see Description of
Arguments)

Unit Alarm Mask

MSK=

12 bytes

Command or Query.
Alarm mask conditions, provides response of 0 (unmasked/active) or 1 (masked)
for each parameter, in form abcdefghijkl, where:
a =Tx FIFO
b=G.703 BPV
c=Tx-AIS
d=Rx AGC Alarm
e=Eb/No Alarm
f=Rx-AIS
g=Buffer slip
h=Ext Reference alarm
i=BUC alarm
j=LNB alarm
k=G.703 Loss of Signal alarm (0 = unmasked, 1 = masked)
Note: For argument k, if G703 CEx FAST option is not installed or Tx clock is not
Internal, only 1=masked is allowed.
Example:
MSK=1110011100

MSK=
MSK?
MSK*
MSK#

MSK?

MSK=abcdefghijkl
(see Description of
Arguments)

Number of Unread
stored Events

N/A

3 bytes

Query only.
Unit returns the number of stored events that remain unread, in the form xxx.
Note: This means unread over the remote control.
Example: NUE=126

N/A

NUE?

NUE=xxx
(see Description of
Arguments)

Advertising
This manual is related to the following products: