Comtech EF Data CDM-570 User Manual

Page 46

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 12

Introduction

MN/CDM570L.IOM

1–6

Table 1-1. Summary of CDM-570/570L Rear Panel Connectors

Connector Group

(Chapter 3

Sect. Ref.)

Name

Connector Type

Function

IF

(Sect. 3.2)

Rx

CDM-570L: Type ’N’ female (L-band)

IF Input

CDM-570: BNC female (70/140MHz
band)

Tx

CDM-570L: Type ’N’ female (L-band)

IF Output

CDM-570: BNC female (70/140MHz

band)

Terrestrial Data

(Sect. 3.3)

Data Interface

25-pin Type ‘D’ female

Serial synchronous data Input/Output

G.703

Data

Balanced

15-pin Type ‘D’ female

G.703

T1 (1544 kbps) / E1 (2048 kbps)

Unbalanced Out BNC 75Ω female

Receive G.703 E1 (2048 kbps)

Unbalanced In

BNC 75Ω female

Transmit G.703 E1 (2048 kbps)

10/100 Ethernet M&C

RJ-45 female

10/100 BaseT management and data

10/100 Ethernet Traffic

RJ-45 female

(w/optional IP Module) Ethernet

Traffic

Utility

(Sect. 3.4)

Remote Control

9-pin Type ‘D’ male

Serial Remote Interface (EIA-232/-

485)

Alarms

15-pin Type ‘D’ male

Form C Alarms (relay closures)

1:1 Control

9-pin Type ‘D’ female

Connection to External 1:1 Controller

External Reference

BNC female

Input/Output

Serial Console

RJ-11 female

(w/optional IP Module) EIA-232 Serial

Console for CDM-570L/IP Module
management

Power/Ground

(Sect 3.5)

AC

See Sect. 3.5.1

Chassis power

DC (optional)

See Sect. 3.5.2

Ground

#10-32 stud

Common Chassis Ground

The European EMC Directive (EN55022, EN50082-1) requires using properly shielded cables for DATA I/O.

These cables must be double-shielded from end-to-end, ensuring a continuous ground shield.

In addition to the connectors listed in Table 1-1, eight LEDs are provided on the rear panel:

• Six of the LEDs, all orange, indicate the interface type currently selected: V.35, RS232,

RS422/EIA530, T1, E1-U, or E1-B.

• For systems in a redundant configuration, a green LED labeled “Online” indicates the

Online/Offline status of the unit.

• When the unit is connected to a 1:N switch, a red LED labeled “1:N CAUTION!

indicates that caution is required, as there may be DC voltages and other control signals
present on certain pins on the 25-pin Data Interface connector.

Also associated with redundancy mode, a slide switch is provided that selects the 1:N mode.

Advertising