Scenario

Problem

Action

2

No Ping response from the

locally connected PC to the
remote CDM-IP or remote

PC.

ICMP response is ‘Request

timed out’.

a)

Verify both CDM-IP’s are in Managed Switch Mode.

b)

Verify IF link between modems for proper settings and carrier
quality (RX signal level, E

b

/N

0

, etc.). It is possible that there is a

spectrum inversion, particularly if you are using the CDM-IP with

RF converter equipment. If this is the case, the signal level &
E

b

/N

0

may be OK, but no data will be received. To correct this,

invert the TX and RX Spectrum on one of the CDM-IPs.

c)

Send a constant ping from the PC 1 ‘ping 172.16.10.2 –t’ to PC
2. In the CDM-IP1, go to Operations and Maintenance/

Diagnostics. Enable ‘Dump Packets transmitted to Satellite

Interface’. Verify that the Pings are being transmitted by

observing 1 packet on CLI every second. If not displayed, re-

verify PC 1 and CDM-IP 1 settings. Disable ‘Dump Packets
transmitted to Satellite Interface’ by entering ‘T’.

d)

Continue sending constant ping from the PC 1 to PC 2. In the

CDM-IP 2, go to Operations Maintenance/Diagnostics. Enable
‘Dump Packets received from Satellite Interface’. Verify that the

Pings are being received by observing 1 packet on CLI every

second. If not displayed, re-verify PC 2 and CDM-IP 2 settings.

Disable ‘Dump Packets received from Satellite Interface’ by
entering ‘R’.

Note: All pings transmitted will require a reply to be

transmitted from the target host. Use the Diagnostics

‘Dump Packets’ tools to isolate where packets are lost
in the CDM-IP duplex paths. Also, always disable

‘Dump Packets’ before sending live traffic.