1 config: rem (remote control), 1 (config: remote control) serial – Comtech EF Data CDM-570 User Manual

Page 94

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 12

Front Panel Operation

MN/CDM570L.IOM

5–8

5.2.2.1.1

CONFIG: Rem (Remote Control)

Remote Control: Local
Serial Ethernet(◄ ►,ENT)


Use the ◄ ► arrow keys to select Local, Serial, or Ethernet, and then press ENTER.

If Local mode is selected, then remote control will be disabled. Remote monitoring is still
possible.

5.2.2.1.1.1 (CONFIG: Remote Control) Serial

NOTE: In Serial mode, in addition to Serial M&C being enabled, Telnet connection (which
enables Telnet M&C for modems configured for redundant operation) is also allowed.

If Serial is selected from the Remote Control submenu and the modem has not been defined as
an EDMAC SLAVE, then the following menu is displayed:

Serial Config: Interface
Baudrate (◄ ►,ENTER)

(CONFIG: Remote Control) Serial: Interface

M&C Bus Interface: RS232
RS485-2W RS485-4W (◄ ►)


Use the ◄ ► arrow keys to select RS232, RS485-2W (2-wire), or RS485-4W (4-wire), and
then press ENTER. Enter the bus address when prompted.

(CONFIG: Remote Control) Serial: Interface Æ RS232

If RS232 is selected, the following menu is displayed:

In RS232 Mode the Bus

Address is fixed at 0000

(CONFIG: Remote Control) Serial: Interface Æ RS485-2W or -4W

If either RS485 mode is selected, edit the address as prompted:

RS485 Bus Address: 0245
(◄ ►,▲ ▼,ENTER)


To edit the RS485 bus address of this unit: First, use the ◄ ► arrow keys to select a digit
to edit, then the ▲ ▼ arrow keys to edit the value of that digit. The valid range of
addresses is from 1 to 9999. Press ENTER when done.