Comtech EF Data CDM-570 User Manual

Page 49

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 12

Introduction

MN/CDM570L.IOM

1–9

FAST System Theory

FAST allows an operator to order a unit precisely tailored for the initial application. When service
requirements change, FAST allows the operator to upgrade the topology of the unit on-location,
within minutes, and without having to remove the unit from the setup. This accelerated upgrade is
possible due to FAST’s extensive use of the programmable logic devices incorporated into Comtech
EF Data products.

FAST Implementation

Comtech EF Data’s FAST system is factory-implemented in the modem. All FAST options are
available through the basic platform unit at the time of order. FAST allows immediate activation
of available options – first, upon entry of the FAST Access Code through the front panel keypad,
and then by setting the desired operational parameters via the front panel, remote control, or Web
Server interfaces.

FAST and FAST-Accessible Hardware Options

Option

Description and Comments

Option

Installation

Method

Low Rate Variable

Data rate 2.4 kbps to 512 kbps

BASE UNIT

Mid-Rate Variable

Data rate 2.4 kbps to 2.048 Mbps

FAST

Full Rate Variable

Data rate 2.4 kbps to 5.0 Mbps

Extended Rate Variable

Data rate 2.4 kbps to 9.98 Mbps

8-PSK/8-QAM

Modulation Type

16-QAM Modulation

Type

R-S Codec

Closed-network Reed-Solomon Codec

HARDWARE

TPC Codec

5 Mbps Turbo Product Codec (IESS-315 compliant)

100W BPSU (CDM-570L only)

100 Watt@30

°C, 90 Watt@50°C, Internal 24V BUC PSU

150W BPSU (CDM-570L only)

150 Watt@50

°C, 180 Watt@30°C, Internal 48V BUC PSU

IP Module Ethernet Interface and IP Options

Option

Description and Comments

Option

Installation

Method

3xDES Data Encryption

Uses NIST certified 3x core
Firmware Version 1.4.0 and later

FAST

IP Header Compression

Firmware Version 1.4.0 and later

Payload Compression

Firmware Version 1.4.0 and later

Quality of Service (QoS)

Firmware Version 1.4.0 and later

IP Module Ethernet Interface

10/100 BaseT Ethernet interface: V1 (MPP-50) or V2 (MPP-70)

HARDWARE


Hardware options for basic modems can be ordered and installed either at the factory or in the
field. The operator can select options that can be activated easily in the field, depending on the

Advertising
This manual is related to the following products: