L.4.2.1 config mdm | buc (block up converter) – Comtech EF Data CDM-570 User Manual

Page 505

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 12

Appendix L

MN/CDM570L.IOM

L–13

L.4.2 ODU (BUC, LNB) Pages

When properly configured to operate with a BUC or LNB, the ‘Config Mdm | BUC’ and ‘Config
Mdm | LNB’
pages allow configuration of the operating parameters specific to the active unit.

Click the ‘Config Mdm’ tab, and then click the ‘BUC’ or ‘LNB’ hyperlink to continue.

L.4.2.1 Config Mdm | BUC (Block Up Converter)

Use this page to configure Block Up Converter parameters, and to display the BUC status for L-Band
operation.


Figure L-3. Config Mdm | BUC page

BUC Configuration

• Use the provided drop-down menus to turn BUC Power Enable, 10 MHz Ref Enable, and

Output Power Enable ON or OFF.

• Assign a BUC Low and High Current Limit value ranging from 0 to 4000 mA.

• Assign a Tx Lockout Frequency and designate the value as a HIGH (+) or LOW (-) limit.

• Assign a BUC Address from 0 to 15.

Click [Submit BUC Controls] to save any changes made to this section.

BUC Status

The values displayed in this section are read-only and cannot be changed. This information
automatically updates every 10 seconds.