L.3.3.1.2.2 (CONFIG: ODU (Outdoor Unit)) LNB

LNB: DC-Voltage 10MHz
Alarm LO Mix (◄ ►, ENT)

Use the ◄ ► arrow keys to select DC-Voltage, 10MHz, Alarm, LO, or Mix, and then press
ENTER.

L.3.3.1.2.2.1 (CONFIG: ODU (Outdoor Unit)) LNB: DC-Voltage

LNB DC Supply Voltage:

13 volts (◄ ►,ENTER)

Use the ▲ ▼ arrow keys to select the value of the LNB DC power supply output voltage as 13
volts
, 18 volts, 24 volts, or Power OFF. Press ENTER when done.

L.3.3.1.2.2.2 (CONFIG: ODU (Outdoor Unit)) LNB: 10MHz

LNB 10MHz Reference:
On Off (◄ ►,ENTER)

Use the ◄ ► arrow keys to select the 10MHz frequency reference for the BUC as On or Off.
Press ENTER when done.

L.3.3.1.2.2.3 (CONFIG: ODU (Outdoor Unit)) LNB: Alarm

Set LNB Current Alarm:
Upper Lower (◄ ►,ENTER)

Use this menu to define the upper and lower limits of the LNB current ‘window.’ If the measured
LNB current falls outside this window, an alarm is generated.

Use the ◄ ► arrow keys to select Upper or Lower. Press ENTER when done.

(CONFIG: ODU (Outdoor Unit)) LNB: Set LNB Current Alarm Æ Upper

LNB Current Alarm Upper
Limit: 200mA (◄ ►,▲ ▼,ENT)

To edit the LNB Current Alarm Upper Limit: First, use the

◄ ►

arrow keys to select a digit

to edit, and then use the

▲ ▼

arrow keys to change the value of that digit. The valid range of

current is from 50 to 600 mA. Press ENTER when done.