Comtech EF Data CDM-570 User Manual

Page 382

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 12

Appendix D

MN/CDM570L.IOM

D–32

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

BUC Low Current
Limit

BCL=

4 bytes

Command or Query.
BUC Low Current Limit, in mA, the form xxxx, where:
xxxx = between 0 and 3000
Example: BCL=0600

BCL=
BCL?
BCL*
BCL#

BCL?

BCL=xxxx
(see Description of
Arguments)

BUC Current

N/A

4 bytes

Query only.
BUC Current, in mA, in the form xxxx, where:
xxxx = between 0 and 9999
If not available, response is 0000.
Example: BDC=3100

N/A

BDC?

BDC=xxxx
(see Description of
Arguments)

BUC Voltage

N/A

4 bytes

Query only.
BUC Voltage, in the form xx.x, where:
xx.x = between 0 and 64.0
If not available, response is 00.0.
Example: BDV=43.6 (BUC DC voltage is 43.6 volts)

N/A

BDV?

BDV=xx.x
(see Description of
Arguments)

BUC 10 MHz
Reference

BFR= 1

byte,

value of 0 or 1

Command or Query.
BUC 10 MHz frequency reference, where:
0 = Disabled
1 = Enabled
Example: BFR=0 (BUC 10MHz reference disabled)

BFR=
BFR?
BFR*
BFR#

BFR?

BFR=x
(see Description of
Arguments)

BUC LO Frequency BLO=

6 bytes

Command or Query.
BUC Tx LO frequency information in the form xxxxxs, where:
xxxxx = LO frequency, in the range of 3000 to 65000 MHz.
All 0’s (000000) disables the feature.
s = sign for the mix (+ or - character)
Terminal Frequency = BUC LO

± TFQ

Example: BLO = 12000+ (BUC LO is 12 GHz, low-side mix)

BLO=
BLO?
BLO*
BLO#

BLO?

BLO=xxxxxs
(see Description of
Arguments)

BUC Output
Enable

BOE= 1

byte,

value of 0 or 1

Command or Query.
BUC Output, where:
0 = Off (output disabled)
1 = On (output enabled)
Example: BOE=1 (BUC output is enabled)

BOE=
BOE?
BOE*
BOE#

BOE?

BOE=x
(see Description of
Arguments)

BUC Output Power
Level

N/A

4 bytes

Query only.
BUC Output Power Level, in Watts, in the form xx.x.
Returns 00.0 when FSK and BUC power are not enabled.
Example: BOL=08.3 (BUC reports output power is 8.3 Watts)

N/A

BOL?

BOL=xx.x
(see Description of
Arguments)