F.2.2 equipment setup, F.2.3 transmit and receive if configuration – Comtech EF Data CDM-570 User Manual

Page 428

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 12

Appendix F

MN/CDM570L.IOM

F–2

F.2.2 Equipment Setup

Step

Task

1

Connect each CDM-IP to the PC via the Ethernet Hub.

2

Connect the TX IF on CDM-IP 1 to RX IF of CDM-IP 2 and vice-versa.

3

Connect the DB-9 end of the console cable to the COM1 or COM2 port of the PC and the RJ-11 end to the

console port at the back of CDM-IP 1.

4

Connect CDM-IP 1 and CDM-IP 2 to suitable power supply and turn them ON.

F.2.3 Transmit and Receive IF Configuration

Step

Task

1

Configure the transmit and receive IF parameters on CDM-IP 1 and CDM-IP 2 via the front panel.

Note: The IF parameters can also be set via console menu, Telnet, Web interface and SNMP, but for this

exercise, it is recommended that the front panel be used.

2

Set the TxPower to minimum level.

3

Before proceeding to next step, make sure that each CDM-IP is appropriately carrier-locked to the other

CDM-IP.

F.2.4 Serial Console Port Command Line Interface (CLI) Configuration

Step

Task

1

Launch the user-supplied terminal emulation program (e.g., HyperTerminal on Microsoft Windows).

2

Select the appropriate COM port to which the DB-9 end of the console cable is connected, and configure

the port as follows:



38,400 bps



8 data bits



No parity



1 stop bit



No hardware flow control

3

Press Enter to bring up the Main Menu.

Advertising
This manual is related to the following products: