3 1:1 control interface connector, db-9f – Comtech EF Data CDM-570 User Manual

Page 73

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 12

Rear Panel Connectors and Pinouts

MN/CDM570L.IOM

3–9

Table 3-6. Alarm Interface Connector Pin Assignments

Pin #

Signal Function

Name

8

15

7

Rx Traffic (De-energized, Faulted)
Rx Traffic (Energized, No Fault)
Rx Traffic

RX-NC
RX-NO
RX-COM

14

6

13

Tx Traffic (De-energized, Faulted)
Tx Traffic (Energized, No Fault)
Tx Traffic

TX-NC
TX-NO
TX-COM

5

12

4

Unit Fault (De-energized, Faulted)
Unit Fault (Energized, No Fault)
Unit Fault

UNIT-NC
UNIT-NO
UNIT-COM

11

3

Rx I Channel (Constellation monitor)
Rx Q Channel (Constellation monitor)

RX-I
RX-Q

10 No

Connection

N/C

2

AGC Voltage (Rx signal level, 0 to 10 volts)

AGC

9

EXT Carrier OFF

EXT-OFF

1 Ground

GND

3.4.3 1:1 Control Interface Connector, DB-9F

The 1:1 Control connection is a 9-pin type ‘D’ female connector (DB-9F). This
connector is used to connect the modem only to a CRS-170 switch in 1:1
redundancy configurations.

Table 3-7. 1:1 Control Interface Connector Pin Assignments

Pin #

Description

Direction

1 Ground

2

Receive Serial Data – auxiliary channel

In

3

Redundancy In 1

In

4

Redundancy In 2

In

5 Ground

6

Transmit Serial Data – auxiliary channel

Out

7

Redundancy Out 1

Out

8

Redundancy Out 2

Out

9

Fused +12 volt

Out

Advertising