Turn power supply on and adjust voltage/current, Adjust preflow gases – Hypertherm HT2000-200 Volt User Manual

Page 105

Advertising
background image

6-10

HySpeed HT2000

Instruction Manual

OPERATION

24

• When using

oxygen, nitrogen, or argon-hydrogen

as the

plasma gas

,

adjust supply regulator to read

120 psi +/- 10 psi (8.2 bar +/- 0.7 bar)

.

When using

air

as the

plasma gas

, adjust supply regulator to read

90 psi

+/- 10 psi (6.2 bar +/- 0.7 bar

).

• Adjust supply regulator for

shield gas

to read

90 psi +/- 10 psi (6.2 bar

+/- 0.7 bar)

.

Turn Power Supply On and Adjust Voltage/Current

7. Turn main disconnect switch ON. See

Status Indicators Before Startup

earlier in this section.

8. Turn on the power supply by depressing the

POWER ON (1)

button

(

PB1

) on the HT2000 power supply. Ensure that the green

POWER ON

indicator illuminates. Hold PB1 down until all of the status indicators

extinguish. If the

POWER ON

light fails to come on, see

Section 4

:

Installation for proper setup.

9. Set the

VOLTAGE

and

CURRENT

on the DR V/C module. Select the

arc current and arc voltage from the

Cut Charts

in this section for the

type and thickness of metal to be test cut.

Adjust Preflow Gases

10. Set

S2

on the gas console to

Test Preflow.

Verify that the plasma gas

pressure gauges (

PG1, PG2

) on the gas console both read 120 psi

(8.2 bar).

11. Look at the oxygen (

FM2

) and/or nitrogen-air (

FM1

) flowmeters on the

gas console and set the

Preflow

plasma gas flow rate % by referring to

the

Cut Charts

and turning the oxygen (

MV3

) and/or nitrogen- air (

MV2

)

preflow flowmeter adjust knobs.

12. Look at the shield gas pressure gauge (

PG3

) on the gas console, and

set to the

Cut Chart

specifications by turning the shield gas adjust knob

(

MV4

).

Note: If you have changed consumable parts or if the power

supply has been off for more than one hour, purge gas

lines by leaving system in

Test Preflow

for one minute.

PLASMA

N

2

/Air

O

2

SHIELD

N

2

/Air

psi

psi

psi

DC

N

2

/Air

O

2

O

2

PLASMA

Cut Flow

PreFlow

PreFlow

Run

10

9

8

7

6

5

4

3

2

1

0

10

9

8

7

6

5

4

3

2

1

0

Test

Preflow

Test

Cutflow

PB1

FM1

FM2

MV2

MV3

MV4

S2

VOLTAGE

CURRENT

PG1

PG3

PG2

Advertising
This manual is related to the following products: