INSTALLATION

4-20

HySpeed HT2000

Instruction Manual

19

Initial Height Sensing (IHS) Connections

Note: If using Command THC, refer to manual #802780.

See page 4-18 for IHS connection to power supply.

IHS Sensor cables/Inductor Probes – IHS to Inductor Probes

The two sensor cables are components of the IHS leads packages – see page 9-43.

Function

IHS End

Color

Probe End

Power (+15 VDC)

4

Red

A

Common

2

Black

B

Signal

1

Clear

C

Shield

3

Braid

The two inductive probes come as part of the IHS torch mounting subassembly – see page 9-43.

IHS Air Supply – Air Supply to IHS Module

The customer must supply the 20 psig regulated shop air and the air hose.

Air Hose Assembly – IHS Module to Inductive Sensor Air Cylinder

The 40-foot air hose is a component of the IHS leads packages – see page 9-43.

Function

Pin

Color

Power (+15 VDC)

A

Brown

Common

B

Blue

Signal

C

Black

14

1

4

2

3

C