Mild steel - beveling consumables, Above water only, 200 amps • o – Hypertherm HT2000-200 Volt User Manual

Page 130: Plasma / air shield

Advertising
background image

HySpeed HT2000

Instruction Manual

6-35

OPERATION

22

Shield

Arc

Approx.

Material

Plasma Gas Flow Rate %

Gas (Air)

Torch-to-work

Initial Torch

Voltage

Motion

Thickness

Preflow

Cutflow

Pressure

Distance

Piercing Height

Setting

Travel Speed

Delay Time

(inches)

(mm)

(O

2

% N

2

%) (O

2

% N

2

%)

(psi)

(inches)

(mm)

(inches)

(mm)

(volts)

(ipm) (mm/min.)

(sec)

1/4

6

12

38

64

0

60

1/8

3

1/4

6

115

160

4060

0.5

.315

8 (14.9 / 50.4 (79.6 / 0

(270

1/8

3

1/4

6

120

120

3000

0.5

3/8

10

SCFH)

SCFH)

SCFH)

1/8

3

1/4

6

120

100

2540

1.0

1/2

12

.157

4

.314

8

120

80

2030

2.0

5/8

15

.157

4

.314

8

125

70

1780

2.0

3/4

20

3/16

5

3/8

10

130

55

1400

2.5

7/8

22

1/4

6

1/2

12

135

45

1140

2.5

1

25

1/4

6

1/2

12

135

35

890

2.5

1 1/4

32

1/4

6

140

22

560

1-1/2

38

1/4

6

150

15

380

1-3/4

44

5/16

8

160

10

250

2

50

5/16

8

170

7

180

Mild Steel - Beveling Consumables

200 amps • O

2

Plasma / Air Shield

Notes:

Set oxygen plasma gas inlet pressure to 120 psi (8.3 bar).
Set nitrogen plasma gas inlet pressure to 120 psi (8.3 bar).
Set shield gas inlet pressure to 90 psi (6.2 bar).

Production cutting above 1" (25 mm) not recommended

Beveling cuts should be made between 45° and 90° to the work surface.

Above Water Only

120833

(cw)

120834

(ccw)

Swirl ring

120258

Electrode

120257

Water Tube

120259

Nozzle

120837

(cw)

120838

(ccw)

Retaining cap

120260

Shield

Advertising