Gas requirements, Introduction – Hypertherm HT2000-200 Volt User Manual

Page 43

Advertising
background image

PRE-INSTALLATION

3-2

HySpeed HT2000

Instruction Manual

20

Gas Requirements

The regulated source gas supplies are provided

by the customer.

Refer to

Section 2

for specifications.

Caution:

Gas supply pressures not within the parameters outlined in Section 2 can cause
poor cut quality, poor consumable life, and operational problems.

Note: If the purity level of the gas is too low or if there are leaks in the supply hoses or

connections, cut speeds can decrease, cut quality can deteriorate, cutting thickness

capability can decrease, and parts life can shorten.

If making hard plumbing connections, avoid using iron pipe. Never use PTFE tape on any

joint preparation. After installation, pressurize the entire system and check for leaks.

Air as Plasma Gas

Refer to

Section 2

for gas specifications.

Two different sources of air can be used to supply the plasma gas requirements of the system: cylinder

compressed air or shop compressed air.

From Cylinder Compressed Air or Shop Air to Gas Console

Use an inert gas hose to connect the air supply to the input connection on the gas console. Hosing can be

purchased through Hypertherm.

When using air as the plasma or shield gas, Hypertherm recommends a three-stage filtration system. See

Appendix section for suggested filtration.

Introduction

Prior to the installation of the HT2000 plasma cutting system, the following requirements must be fulfilled.

Please read these requirements carefully. Their purpose is to aid you in the installation of your plasma cutting

system and to allow maximum performance.

Installation and service of the electrical and plumbing systems must conform to national or local
electrical and plumbing codes. This work should be performed only by qualified, licensed personnel.

Note: Before positioning the power supplies, see Upon Receipt in the Installation section (Section

4) of this manual.

If questions arise at any time, call Technical Service listed in the front of this manual or your authorized

Hypertherm distributor.

Advertising
This manual is related to the following products: