System grounding requirements, Suggested ground cable routing, Appendix f system grounding – Hypertherm HT2000-200 Volt User Manual

Page 286

Advertising
background image

HySpeed HT2000

Instruction Manual

f-1

21

System Grounding Requirements

The plasma system must be grounded for safety reasons and to suppress EMI:

Safety

The entire system – power supply, accessory enclosures, and worktable – must be grounded to

protect it and the operator from a ground fault. The protective earth (PE) ground connections must be

installed by a licensed electrician and conform to national and local codes.

EMI Suppression

If allowed by national and local codes, the ground system can also be used to suppress

EMI (electromagnetic interference). Below is a guide to configure the plasma system for minimal EMI. See

Electromagnetic Compatibility in this manual for additional information.

Suggested Ground Cable Routing

Power Supply

Connect the power supply to the PE ground terminal, using a properly sized color-coded conductor. This PE

ground is connected to the service ground through the line disconnect switch. See the Installation section for

further information on the power cord and the line disconnect switch.

Equipment Grounding

All accessory modules that receive power from the plasma power supply must also use the power supply’s

ground – either by connection to the PE terminal of the power supply, or by direct connection to the

equipment ground conductor. Each module should have only one connection to ground to avoid ground loops.

If any enclosure is grounded to the work table, the work table must be grounded to the power supply.

Effective grounding for EMI reduction is highly dependent upon the installation configuration. Two acceptable

configurations are shown in Figures f-1 and f-2.

The RHF console should be installed near the work table, and grounded directly to it. Other modules should

be installed near the power supply, and grounded directly to it (Figure f-1).

All modules may also be installed near the work table, and grounded directly to it (Figure f-2). Do not ground

the RHF console directly to the power supply.

The customer must furnish all conductors for equipment grounding. Grounding conductors may be purchased

through Hypertherm in any length specified by the customer (Part No. 047058). The conductor may also be

Appendix F

SYSTEM GROUNDING