Hypertherm HT2000-200 Volt User Manual

Page 47

Advertising
background image

PRE-INSTALLATION

3-6

HySpeed HT2000

Instruction Manual

19

Type SO

input power cable with a conductor temperature rating of 140°F (60°C) according to the following

requirements:

Input Voltage

Cable Size (AWG)

Current Rating

200 VAC

1

107 amps

208 VAC

1

107 amps

220 VAC

1

107 amps

240 VAC

1

107 amps

380 VAC

4

69 amps

400 VAC

4

69 amps

415 VAC

4

69 amps

440 VAC

6

52 amps

480 VAC

6

52 amps

600 VAC

8

39 amps

Positioning the Power Supply

Positioning the Power Supply

Prior to making electrical connections to the power supply, position the supply as follows:

Note: A lifting eye is provided for moving the power supply into place with a crane or hoist. It may

also be moved by forklift if the forks are long enough to extend the entire length of the

base. Care should be used when lifting with the forks so that the underside of the power

supply is not damaged.

1. Place the power supply in an area that is free of excessive moisture, has proper ventilation, and is

relatively clean. Allow room for accessing the sides of the power supply for servicing.

2. Place the power supply so that air flow is not blocked in any way. (Cooling air is drawn in through the front

panel grating, and is exhausted through the rear of the unit by a cooling fan.)

3. Do not place any filter device over the air intake locations. This reduces cooling efficiency and VOIDS THE

WARRANTY.

4. After placement of the power supply, the line disconnect switch box can be placed close to the power

supply for safety purposes.

WARNING

Remove all electrical connections to power supply before moving or positioning. Transporting
unit can cause personal injury and equipment damage.

Advertising
This manual is related to the following products: