6-12

HySpeed HT2000

Instruction Manual

OPERATION

21

2. Torch-to-work distance is not correct (check

Cut Chart

information).

3. Cutting speed is not correct (check

Cut Chart

information).

4. Arc current is not correct (check

Cut Chart

information).

5. Damaged consumable parts (see

Changing Consumable Parts

).

• Short consumable life. Causes can be:

1. Arc current, arc voltage, travel speed, motion delay, gas flow rates, or initial torch height not set as

specified in

Cut Charts

.

2. Attempting to cut highly magnetic metal plate (some metals such as armor plate with a high nickel

content) will shorten consumable life. Long consumable life is difficult to achieve when cutting plate that

is magnetized or becomes magnetized easily. Call Hypertherm's Technical Service (1-800-643-9878) if

you suspect the type of metal you are cutting is causing shortened consumable life.

3. Not beginning or ending cut on plate.

Also see

Cutting Techniques

later in this section for methods to improve cutting performance.

Technical Questions

Claims for defective merchandise –

All units shipped from Hypertherm undergo rigorous quality control

testing. However, if your system does not function correctly:

1. Recheck all pre-installation and installation requirements and connections.

2. If you are unable to solve the problem, call your distributor. He (she) will be able to help you, or refer you

to an authorized Hypertherm repair facility.

3. If you need assistance, call Hypertherm's Technical Service department at 1-800-643-9878.

Cut Charts

The Cut Charts on the following pages provide the necessary information in order for the operator using the

system to be successful in plasma arc cutting. The HT2000 provides a wide travel speed operating window:

usually ± 10 ipm (± 254mm/min) on most materials. The data listed in the charts are for making drop cuts with

minimal dross.

Caution:

Before cutting, check all settings and adjustments and check for damaged torch
parts and worn consumable parts.

Conversions

1 inch = 25.4 mm; 1 scfh = 28.316 liter/hour; 1 psi = .0689 bar = 6.895 KPa

Advertising