Check pump, motor and solenoid valve (v1) – Hypertherm HT2000-200 Volt User Manual

Page 172

Advertising
background image

MAINTENANCE

HySpeed HT2000

Instruction Manual

8-27

20

Check Pump, Motor and Solenoid Valve (V1)

1. If coolant is not flowing, check to see if motor and valve V1 are getting 240VAC. Note: The 240VAC relay

(CR3) on PCB1 will not close until the first five (5) interlocks (STATUS) indicators are satisfied. (See

Startup Sequence

flowchart)

2. If motor, pump and valve all seem to be functioning and the flow is not sufficient, replace the pump and

motor assembly.

Figure 8-7

Plumbing Schematic of Power Supply Reservoir Assembly

with RHF Console and Torch

Cathode Block
(in back of
power supply)

Remote High Frequency
Console

Heat
Exchanger

Check
Valve

Flow Switch
FS1

Solenoid Valve
V1

Particulate
Filter

Coolant Reservoir

Float Switch
LS1

Temperature Switch
TS1

Torch

Pump with
Relief Valve

Advertising