System checkout – Hypertherm HT2000-200 Volt User Manual

Page 90

Advertising
background image

POST-INSTALLATION

HySpeed HT2000

Instruction Manual

5-3

19

System Checkout

The following procedure assumes the system includes an IHS system, and a Digital Remote (DR) V/C control

module. Refer to Figure 5-1.

Set Switches and Check Torch

1. Ensure that the unit switches listed below are positioned as follows:

The main disconnect switch for the power supply is set to

Off

.

The

Test Preflow/Run/Test Cut Flow

toggle switch on the gas console is set to

Run.

2. Ensure that the proper consumables are installed in the torch. Refer to the

Cut Charts

in

Section 6

to

choose the correct consumables for your cutting needs. See also

Changing Consumable Parts

in

Section 6

.

3. Ensure that the torch is squared to the material. Refer to

Section 4

for the torch alignment procedure.

Turn Gases On

4. Set the plasma gas select switch on the gas console to

N

2

/Air

or

O

2

.

5. Turn the required supply gases

On.

• When using

oxygen, nitrogen,

or

argon-hydrogen

as the

plasma gas

, adjust supply regulator to read

120 psi +/- 10 psi (8.3 bar +/- 0.7 bar)

.

When using

air

as the

plasma gas

, adjust supply regulator to read

90 psi +/- 10 psi (6.2 bar +/-

0.7 bar).

• Adjust supply regulator for

shield gas

to read

90 psi +/- 10 psi (6.2 bar +/- 0.7 bar)

.

Turn Power Supply On and Adjust Voltage/Current

6. Set the main disconnect switch for the power supply to the

On

position. See

Status Indicators Before

Startup

in

Section 6

. Depress the

POWER ON (1)

button on the power supply.

Ensure the green

POWER ON

indicator on the power supply lights.

7. Set the

VOLTAGE

and

CURRENT

on the DR V/C module. Select the arc current and arc voltage from the

Cut Charts

in

Section 6

for the type and thickness of metal to test cut.

Advertising
This manual is related to the following products: