PRE-INSTALLATION

3-4

HySpeed HT2000

Instruction Manual

24

WARNING

Propylene glycol and benzotriazole are irritating to skin and eyes, and harmful or fatal if
swallowed. Upon contact, flush skin or eyes with water. If swallowed, drink water and call a
physician immediately. Do not induce vomiting.

Torch Coolant Requirements

The power supply is shipped to the customer without any coolant in the tank. Hypertherm recommends a

mixture of 30% propylene glycol, 69.9% deionized water, and .1% benzotriazole. This mixture resists freezing

to +10° F (-12° C) and contains a corrosion inhibitor (benzotriazole) to protect copper surfaces in the coolant

loop. This mixture is available in one-gallon containers by ordering 028872. 100% propylene glycol is

available by ordering 028873.

Caution:

For operating temperatures colder than the temperature stated above, the
percentage of propylene glycol must be increased. Failure to do so could result in
a cracked torch head, hoses, or other damage to the torch coolant system due to
the torch coolant freezing.

See Figure b-1 chart in

Appendix B

to determine if a stronger propylene glycol/purified water solution is

needed for your particular application.

Observe the warning and cautions below. Refer to the Material Safety Data Sheets in Appendix B for data on

safety, handling, and storage of propylene glycol and benzotriazole.

Caution:

Always use propylene glycol in the coolant mixture. Do not use anti-freeze in place
of propylene glycol. Antifreeze contains corrosion inhibitors that will damage the
torch coolant system.

Caution:

Always use purified water in the coolant mixture in order to prevent corrosion in the
torch coolant system. The hardness of the purified water should be between .206
and 8.5 ppm. If using a conductivity meter to measure water purity, the
recommended level is between 0.5 and 18 µSiemens/cm at 77° F (25° C).

Grounding Requirements

Proper grounding is essential for reasons of personal safety and to prevent emission of high frequency

interference. See Appendix F for system grounding requirements.

Connect the worktable to a high-quality earth ground from 3 feet to 20 feet of the table. A suitable ground

consists of a solid copper rod of at least 1/2-inch diameter driven to a depth of at least 8 feet into the earth

below the permanent moisture level. For additional information consult the National Electric Code, Article 250,

Section H

Grounding Electrode System

, or other appropriate code.