Hypertherm HT2000-200 Volt User Manual

Page 15

Advertising
background image

TABLE OF CONTENTS

iv

HySpeed HT2000

Instruction Manual

19

Remote High Frequency Console ....................................................................................................................2-6
Gas Console ....................................................................................................................................................2-7
Motor Valve Console........................................................................................................................................2-7
Argon/Hydrogen Console.................................................................................................................................2-8
Digital Remote (DR) V/C Control .....................................................................................................................2-8
Programmable Remote (PR) V/C Control ........................................................................................................2-9
Initial Height Sensing .....................................................................................................................................2-10
Timer/Counter ................................................................................................................................................2-10
Water Muffler..................................................................................................................................................2-10

Section 3

PRE-INSTALLATION ...........................................................................................................................3-1

Introduction ...............................................................................................................................................................3-2
Gas Requirements....................................................................................................................................................3-2

Air as Plasma Gas ...........................................................................................................................................3-2
Oxygen, Nitrogen, or Argon/Hydrogen as Plasma Gas ...................................................................................3-3
Shield Gas........................................................................................................................................................3-3

Torch Coolant Requirements....................................................................................................................................3-4
Grounding Requirements..........................................................................................................................................3-5
Power Requirements ................................................................................................................................................3-5

Line Disconnect Switch ....................................................................................................................................3-5
Power Cable.....................................................................................................................................................3-5
Positioning the Power Supply ..........................................................................................................................3-6

Electrical Configurations ...........................................................................................................................................3-7

240/480V Linkboard Configurations.................................................................................................................3-7
220/380/415V Transformer T1 and T2 Configurations.....................................................................................3-8

Connecting the Power ............................................................................................................................................3-10
Torch Lifter Requirement ........................................................................................................................................3-11
Optional Equipment ................................................................................................................................................3-11

Water Muffler..................................................................................................................................................3-11
Initial Height Sensing (IHS) ............................................................................................................................3-12

Section 4

INSTALLATION ...................................................................................................................................4-1

Upon Receipt ............................................................................................................................................................4-2
Claims ......................................................................................................................................................................4-2
Module Grounding and Grounding Checks ..............................................................................................................4-3
Noise Levels .............................................................................................................................................................4-3
System Units Placement...........................................................................................................................................4-4
Power Supply Connections.......................................................................................................................................4-6
Initial Height Sensing (IHS) Connections................................................................................................................4-20
Gas Console Connections ......................................................................................................................................4-24
RHF and Motor Valve Consoles to Torch Connections ..........................................................................................4-28

Routing the Torch Leads................................................................................................................................4-28
Connecting the HF Torch Leads to the RHF Console....................................................................................4-28
Connecting the HF Torch Leads to the Torch ................................................................................................4-30
Connecting the Off-Valve Cable and Plasma Hose from the Torch to the Motor Valve Console ..................4-30

Optional Power Supply Connections ......................................................................................................................4-32

Advertising
This manual is related to the following products: