Mild steel, Above water only, 200 amps • n – Hypertherm HT2000-200 Volt User Manual

Page 112: Plasma / co, Shield

Advertising
background image

HySpeed HT2000

Instruction Manual

6-17

OPERATION

22

Shield

Arc

Approx.

Material

Plasma Gas Flow Rate %

Gas (CO

2

)

Torch-to-work

Initial Torch

Voltage

Motion

Thickness

Preflow

Cutflow

Pressure

Distance

Piercing Height

Setting

Travel Speed

Delay Time

(inches)

(mm)

(N

2

%)

(N

2

%)

(psi)

(inches)

(mm)

(inches)

(mm)

(volts)

(ipm) (mm/min.)

(sec)

3/16

5

50

60

60/4

1/8

3

1/4

6

120

130

3300

0.5

1/4

6

(62.3

(75.0

(270

1/8

3

1/4

6

125

110

2800

1.0

3/8

10

(SCFH)

SCFH)

SCFH)

1/8

3

1/4

6

130

85

2160

1.5

1/2

12

1/8

3

1/4

6

130

55

1400

2.0

5/8

15

.157

4

.314

8

135

45

1140

2.0

3/4

20

3/16

5

3/8

10

145

25

635

2.5

7/8

22

1/4

6

1/2

12

150

20

510

3.0

1

25

1/4

6

1/2

12

160

15

380

3.0

1-1/4

32

1/4

6

165

10

250

1-1/2

38

1/4

6

175

5

130

Mild Steel

200 amps • N

2

Plasma / CO

2

Shield

This gas combination may be used when cut edge quality and surface nitriding are less important. Electrode life is

extended when using this combination.

Notes:

Set plasma gas inlet pressure to 120 psi (8.3 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)

Production cutting above 1" (25 mm) not recommended

Above Water Only

020424
Shield

120837
Retaining cap

020608
Nozzle

020607
Swirl ring

020415
Electrode

Advertising
This manual is related to the following products: