Power Cable to Power Supply

To connect the power cable to the 400V CE power supplies (073198 and 073199), refer to
Appendix E. For all other power supplies, use the procedure below.

1. Insert the power cable through the strain relief at the lower left rear of the power supply. Connect the

power cable leads to

TB1

at the rear center panel of the right side.

2. Connect the power leads to the

L1

,

L2

, and

L3

terminals of

TB1.

See Fig. 3-3

.

3. Connect the ground lead to the stud as shown.