Relay board led status conditions (continued), Test cutflow, Run preflow – Hypertherm HT2000-200 Volt User Manual

Page 169: Run cutflow

Advertising
background image

MAINTENANCE

8-24

HySpeed HT2000

Instruction Manual

20

Relay Board LED Status Conditions (continued)

(The following LEDs are illuminated during the conditions shown)

Test Cutflow

D6: +12VDC

D8: O

2

Solenoid Valve (SV1A), if in O

2

Mode

D10: Plasma Off-Valve Solenoid Valve (SV5)

D12: Cutflow Solenoid Valve (SV4A)

D16: N

2

Solenoid Valve (SV1B), if in N

2

Mode

D19: Cap Sense Solenoid Valve (SV7)

D20: Output Enable

D26: Spare

D28: Shield Gas Solenoid Valve (SV6)

Run Preflow

D6: +12VDC

D7: Pilot Arc Relay (CR1)

D8: O

2

Solenoid Valve (SV1A), if in O

2

Mode

D10: Plasma Off-Valve Solenoid Valve (SV5)

D11: Preflow Solenoid Valve (SV4B)

D14: Main Contactor (CON1)

D15: DC ON Lights (LT1/LT2)

D16: N

2

Solenoid Valve (SV1B), if in N

2

Mode

D17: N

2

Preflow Solenoid Valve (SV2)

D18: O

2

Preflow Solenoid Valve (SV3)

D19: Cap Sense Solenoid Valve (SV7)

D20: Output Enable

D26: Spare

D28: Shield Gas Solenoid Valve (SV6)

Run Cutflow

D6: +12VDC

D8: O

2

Solenoid Valve (SV1A), if in O

2

Mode

D10: Plasma Off-Valve Solenoid Valve (SV5)

D12: Cutflow Solenoid Valve (SV4A)

D14: Main Contactor (CON1)

D15: DC ON Lights (LT1/LT2)

D16: N

2

Solenoid Valve (SV1B), if in N

2

Mode

D19: Cap Sense Solenoid Valve (SV7)

D20: Output Enable

D24: Arc Transfer

D26: Spare

D28: Shield Gas Solenoid Valve (SV6)