INSTALLATION

4-4

HySpeed HT2000

Instruction Manual

24

Gas or water

Torque Specification

hose size

lbf-in

lbf-ft

kgf-cm

up to 3/8" (10mm)

75-85

6.25-7

86-98

1/2" (12 mm)

360-480

30-40

415-550

System Units Placement

• Ground all external modules in the system to earth. See Appendix F.

• Position all required units prior to making electrical, gas, and interface connections.

• Note that the motor valve console must be located within 10 ft (3 m) of the torch, and the IHS console must

be located within 40 ft (12 m) of the torch.

• To prevent leaks in the system, tighten all gas and water connections to the following specifications:

Figure 4-2

Typical Unit Placement for Gantry Cutter

Motor Valve Console

Torch w/IHS Probes

Water In

Water Filter

Water Muffler
Pump

Power In

Power In

Machine Control

Power Supply

Gas Console

Remote V/C

Plasma
Gas In

Shield
Gas In

Air In

IHS Console

RHF Console

Torch with
Water Muffler

Use 2 wrenches when tightening to prevent damage to the mating component.