SPECIFICATIONS

HySpeed HT2000

Instruction Manual

2-5

22

Specifications

System Requirements

Power Requirements:

Refer to power supply specifications below:

Gas Requirements:

Plasma Gas Types ......................................Oxygen (O

2

), Nitrogen (N

2

), Air, Argon-Hydrogen (65% Argon;

35% Hydrogen)

Shield Gas Types ..........................................Air, Nitrogen (N

2

), Carbon Dioxide (CO

2

)

Gas Quality:

Oxygen ..........................................................99.5% pure (liquid gas recommended)

Nitrogen ........................................................99.995% pure (liquid gas recommended)

Air ..................................................................Clean, dry, oil-free (compressed or liquid gas recommended)

Carbon Dioxide..............................................99.5% pure (compressed or liquid gas recommended)

Plasma Gas Inlet Pressures and Flowrates:

Air ..................................................................90 psi +/- 10 psi (6.2 bar +/- 0.7 bar) at 82 scfh (2322 l/h)

Oxygen ..........................................................120 psi +/- 10 psi (8.3 bar +/- 0.7 bar) at 90 scfh (2549 l/h)

Nitrogen ........................................................120 psi +/- 10 psi (8.3 bar +/- 0.7 bar) at 80 scfh (2265 l/h)

Argon-Hydrogen ............................................120 psi +/- 10 psi (8.3 bar +/- 0.7 bar) at 105 scfh (2973 l/h)

Shield Gas Inlet Pressures and Flowrates:

Air ..................................................................90 psi +/- 10 psi (6.2 bar +/- 0.7 bar) at 280 scfh (7929 l/h)

Carbon Dioxide..............................................90 psi +/- 10 psi (6.2 bar +/- 0.7 bar) at 220 scfh (6230 l/h)

Nitrogen ........................................................90 psi +/- 10 psi (6.2 bar +/- 0.7 bar) at 275 scfh (7787 l/h)

Oxygen ..........................................................120 psi +/- 10 psi (8.3 bar +/- 0.7 bar) at 35 scfh (991 l/h)

Power Supply

Maximum OCV (U

0

) ......................................280 VDC

Output Current (I

2

) ........................................40 to 200 amps

Output Voltage (U

2

) ......................................150 VDC

Duty Cycle Rating (X) ..................................100% up to 30kW. Beyond 30kW, Duty Cycle (X)=

(30kW/ Actual Power)

2

Eg: If Actual Power = 32kW, then

Duty Cycle (X)= (30kW/32kW)

2

= 88%

Ambient Temperatures/Duty Cycle................Power supplies will operate between +14° and 104°F (-10°

and +40°C). Power supplies operated in an ambient

temperature above 86°F (30°C) may show some decrease in

duty cycle.

Power Factor (cos

ϕ

) ......................................0.86

Input Power

(Input Voltage (U

1

) x Input Current (I

1

))

:

#073054

with THC/

#073106

without THC ....240/480 VAC, 3PH, 60 Hz, 90/45 amps

#073064

with THC/

#073105

without THC ....208 VAC, 3PH, 60 Hz, 104 amps

#073065

with THC/

#073107

without THC ....220/380/415 VAC, 3PH, 50 Hz, 98/57/52 amps

#073198

with THC/

#073199

without THC ....400 VAC, CE, 3PH, 50 Hz, 56 amps

(See Appendix E to connect incoming power)

#073196

with THC ........................................440/460 VAC, 3PH, 50-60 Hz, 49/47 amps

#073063

with THC/

#073104

without THC ....200 VAC, 3PH, 50 Hz, 108 amps

#073066

with THC/

#073108

without THC ....600 VAC, 3PH, 60 Hz, 36 amps

Advertising