MAINTENANCE

8-22

HySpeed HT2000

Instruction Manual

22

Number

of blinks

Explanation

1

Indicates that the IHS Complete signal has not been returned within 30 seconds after the

plasma START command has been given.

2

Indicates that an "interlock" error has occurred.

3

Indicates that the HOLD input (for multi-torch systems) was not released within 30 seconds

after the end of preflow.

4

Indicates that there was no transfer within 300ms.

5

Indicates that transferred current arc was lost during ramp up.

6

Indicates that the current was lost from chopper #1 (CH1).

7

Indicates that the current was lost from chopper #2 (CH2).

8

Indicates that transferred current arc was lost during ramp down.

9

Indicates that the software has an error.

10

Indicates that the input voltage has dropped below 15% of the nominal value.

Eg: Input voltage for a 480V power supply drops below 408V.

Figure 8-5

Error Codes

Analog Board LED Functions

D4

D3

D6

Rec 3

Rec 1

Rec 2

D3: +12VDC

D4: Chopper Current CH2

D6: Chopper Current CH1