HySpeed HT2000

Instruction Manual

6-39

OPERATION

22

Changing the Water Tube

Problems and causes you may find with a defective or improperly installed water tube:

• Short electrode life: Water tube not screwed in tightly

• Flow switch interlock shutting down the system: Water flow restricted due to loose water tube.

• Humming or rattling sound coming from the torch: Water tube bent or loose

If you suspect a problem with the water tube, you may need to replace it.

1. Disconnect power supply from power source.

2. Remove all consumables from torch (see

Changing Consumable Parts

).

3. Look for any damage or bends in the water tube.

4. Remove and replace the water tube by using the water tube wrench (027347) supplied by Hypertherm –

Fig. 6-8.

When installing water tube, do not over tighten!

Snug down by hand only.

Figure 6-8

Changing the Water Tube

WARNING

Always disconnect the power supply

from the main power source before

inspecting or changing the torch parts.