MAINTENANCE

HySpeed HT2000

Instruction Manual

8-11

24

3. The green POWER ON pushbutton

switch PB1 is pressed, the fans are
operating, but the green POWER
ON indicator does not illuminate.

3.1. Pushbutton PB1 was not held down for a long enough

period of time.

Press and hold PB1 for a minimum of 5 seconds.

3.2. Relay CR1 on the power distribution board is defective.

Check that CR1 switches when POWER ON pushbutton is

pressed. See Figure 8-2 for location of CR1. If CR1 is

defective, replace PCB1.

3.3. One or more of the STATUS LEDs remains illuminated,

indicating a fault condition.

To troubleshoot STATUS fault conditions, see

Status LED

Troubleshooting

later in this section.

4. The green POWER ON indicator is

illuminated, the START command is
given and DC ON indicator is
illuminated, but there is no high
frequency and no pilot arc.

4.1. There is no spark between the spark gap electrodes.

Clean (with emery cloth), align and reset the electrode gaps

to .020" (0.51 mm), if necessary. The electrode surfaces

between the gaps should be flat. If surfaces are rounded,

replace and reset the gap. See Figure 9-12 for part number

information.

• Inspect the high voltage transformer T1 in the RHF

console for overheating. See Figure 9-11 for location of

T1. Replace T1 if overheating.

• Check for 120VAC at T1 after START command is given.

Note that door interlock switches S1 and S2 have to be

closed in order to pass the START sequence.

Switches will close in both IN position, and if pulled OUT.

• If there is no 120VAC at T1, use wiring diagrams in

Section 10

and check pins, connectors and associated

wiring from T1 to relay board PCB4. If connections are

OK, there may be a problem with either PCB4 or PCB2.

See sheet 4 of 13 in

Section 10

for location of the relay

that controls RHF transformer T1.

Problem

Possible Causes

/ Solutions