PRE-INSTALLATION

HySpeed HT2000

Instruction Manual

3-11

19

Power Cable from Power Supply to Power Source.

1.

Be certain that the line disconnect switch is in the OFF position.

2. Connect the power cord leads to the line disconnect switch following local and applicable electrical codes.

Optional Equipment

Water Muffler

The water table provides the supply of water to the Water Muffler pump. It is

mandatory

that this water be

filtered. A strainer filter, Hypertherm 027009, is provided with all Water Muffler systems.

Plumbing Requirements

Four feet

of

3/4 inch

I.D.

#12

hosing is required to attach the filter to the pump. It is important that the pump

be placed as close as possible to the water table. Longer distances result in pump priming problems, as well

as water lag problems during start up. This results in excessive noise and smoke during the initial starting.

Water pump and water hosing can be purchased by the customer, or supplied by Hypertherm when ordering a

Water Muffler system. Please refer to Water Muffler System part numbers listed below, and Water Muffler

instruction manual 802050 for further information.

Torch Lifter Requirement

The system requires a high-quality, motorized torch lifter with sufficient travel to cover all cutting thickness

requirements. A lifter which provides

10 inches (254 mm) of vertical travel

should be adequate. The unit

should have a constant speed of at least

20 ipm (508 mm/min)

and braking should be positive. A unit which

drifts through the stop point is not acceptable.

WARNING

The line disconnect switch must remain in the OFF position during the rest of the pre-
installation and installation of the system!