MAINTENANCE

8-10

HySpeed HT2000

Instruction Manual

19

Troubleshooting

The troubleshooting section is presented by following normal operational sequence.

Before troubleshooting for specific problems, be sure that unit passes

Initial Checks

as outlined earlier in this

section.

WARNING

SHOCK HAZARD: Always use caution when servicing a power supply when the covers are
removed. Dangerous voltages exist within the power supply which could cause injury or death. If
questions or problems arise during servicing, call the Hypertherm Technical Services Department
at 1-800-643-9878.

1. The green POWER ON pushbutton

switch PB1 is pressed, but the fans
are not operating and the green
POWER ON indicator does not
illuminate.

1.1. The green POWER ON (1) PB1 pushbutton is defective.

Check that switch is operating correctly, and that good

contact is being made. The POWER ON switch is normally

open.

1.2. The red POWER OFF (0) PB2 pushbutton is defective.

Check that switch is operating correctly, and that good

contact is being made. The POWER OFF switch is normally

closed.

1.3. Associated wiring not making good contact.

Check wiring and repair or replace, if necessary.

2. The green POWER ON pushbutton

switch PB1 is pressed, the POWER
ON indicator illuminates, but the
fans are not running.

2.1. CR2 on the power distribution board is defective.

Check that CR2 switches when POWER ON pushbutton is

pressed. See Figure 8-2 for location of CR2. If CR2 is

defective, replace PCB1.

2.2. Connector from power distribution board is not seated

securely.

Check pins, connectors and associated wiring for good

continuity. Repair or replace, if necessary.