Aluminum, Above water, 3" under water – Hypertherm HT2000-200 Volt User Manual

Page 127: 100 amps • air plasma / air shield

Advertising
background image

6-32

HySpeed HT2000

Instruction Manual

OPERATION

22

Shield

Arc

Approx.

Material

Plasma Gas Flow Rate %

Gas (Air)

Torch-to-work

Initial Torch

Voltage

Motion

Thickness

Preflow

Cutflow

Pressure

Distance

Piercing Height

Setting

Travel Speed

Delay Time

(inches)

(mm)

(Air %)

(Air %)

(psi)

(inches)

(mm)

(inches)

(mm)

(volts)

(ipm) (mm/min.)

(sec)

Shield

Arc

Approx.

Material

Plasma Gas Flow Rate %

Gas (Air)

Torch-to-work

Initial Torch

Voltage

Motion

Thickness

Preflow

Cutflow

Pressure

Distance

Piercing Height

Setting

Travel Speed

Delay Time

(inches)

(mm)

(Air %)

(Air %)

(psi)

(inches)

(mm)

(inches)

(mm)

(volts)

(ipm) (mm/min.)

(sec)

1/8

3

48

39

60

3/32

2.5

3/16

5

135

110

2800

3/16

5

(55.3

(44.9

(270

1/8

3

1/4

6

140

90

2290

0.5

1/4

6

SCFH)

SCFH)

SCFH)

1/8

3

1/4

6

145

70

1780

0.5

3/8

10

1/8

3

1/4

6

145

50

1270

0.5

1/2

12

1/8

3

150

40

1010

5/8

15

.157

4

155

30

760

3/4

20

3/16

5

160

25

635

Aluminum

100 amps • Air Plasma / Air Shield

This gas combination gives good cut speed, low dross levels and is very economical.

Notes:

Set plasma gas inlet pressure to 90 psi (6.2 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)

Production cutting above 3/8" (10 mm) not recommended

Above Water

1/8

3

48

39

70

5/64

2

5/32

4

135

100

2650

3/16

5

(55.3

(44.9

(280

1/8

3

1/4

6

140

80

2050

0.5

1/4

6

SCFH)

SCFH)

SCFH)

1/8

3

1/4

6

145

60

1510

0.5

3/8

10

1/8

3

1/4

6

150

40

1000

0.5

1/2

12

1/8

3

155

30

750

3" Under Water

020448
Shield

120837
Retaining cap

020611
Nozzle

020607
Swirl ring

120547
Electrode

Advertising
This manual is related to the following products: