Hypertherm HT2000-200 Volt User Manual

Page 161

Advertising
background image

MAINTENANCE

8-16

HySpeed HT2000

Instruction Manual

19

Problem

Possible Causes

/ Solutions

3. COOLANT LEVEL LED

illuminated:

3.1. Coolant level is low.

This LED will extinguish when a proper coolant level in the

coolant reservoir is maintained. Level switch LS1 is located

in the coolant reservoir, and will open when it senses that

coolant level is too low.

• Check coolant level.

• If coolant level is adequate, check to see if LS1 switch is

closed.

• Check connections and associated wiring from LS1 to

PCB1.

Repair and/or replace defective component(s), if necessary.

4. SHIELD GAS/CAP LED

illuminated:

4.1. Shield gas pressure too low.

This LED will extinguish when shield gas pressure of 12 psi

(0.83 bar) or greater is sensed by PS3 (located in the RHF

console).

• Check to see that shield gas supply is set according to the

Cut Charts

in this manual.

• Verify that all shield gas connections are secure, and that

there are no leaks in any hoses connected to the RHF

console or gas console.

4.2. Torch cap not tightened securely.

If the torch retaining cap is not tightened securely, or there

is debris in the retaining cap, shield gas may escape and

cause pressure switch PS3 to remain open.

• Listen at the torch for a hissing sound during startup.

• Remove retaining cap and check for debris or O-ring

damage. Clean or replace, if necessary. See

Changing

Consumable Parts

in the

Operation

section.

4.3

.

Pressure switch PS3 in RHF console not functioning.

PS3 is normally open, and closes when shield gas pressure

is 12 psi (0.83 bar) or greater.