INSTALLATION

4-28

HySpeed HT2000

Instruction Manual

19

RHF and Motor Valve Consoles to Torch Connections

See pages 4-6 through 4-9 for RHF connections to power supply, and page 4-12 for motor valve console

connection to power supply. See also page 4-26 for RHF and motor valve console connections to gas

console.

Routing the Torch Leads

Prior to connecting the torch leads to the RHF console, motor valve console and torch, the torch leads must

be routed between the cutting machine, RHF console, motor valve console and the torch. See Figure 4-2 for

an example. You will generally need to route the leads through a festoon or a power track.

Caution:

Before routing the leads, make sure the torch is removed from the torch leads.
Damage to the torch could result from dropping, banging, or scraping. Once the
torch leads have been routed, proceed with torch connections.

Connecting the HF Torch Leads to the RHF Console

Torch Leads – HF Torch Leads to RHF Console – Fig. 4-16

A. Route the HF torch leads through the

Torch Brass Fitting

on the RHF console and connect the

Torch

Coolant Hose (w/Red Band)

to the red fitting on the brass cathode block located in the RHF console.

Tighten using a 1/2" open-end wrench.

B. Connect the

Torch Coolant Hose (w/ Green Band)

to the green fitting on the brass cathode block.

Tighten using a 1/2" open-end wrench.

C. Connect the

Cap-On Sensor Hose (Gray)

to the adapter in the console.

D. Connect the

Pilot/Shield Gas Hose (Blue)

to the bulkhead adapter.

24

Torch End

Pilot/Shield Gas (Blue)

Gray

Red

Green

Red

Green

Gray

Pilot/Shield Gas (Blue)

HF Console End

Part No.

Length

Part No.

Length

028657

10 ft (3 m)

028658

15 ft (4.5 m)

028659

20 ft (6 m)

028546

25 ft (7.5 m)

028660

30 ft (9 m)

028661

35 ft (10.6 m)

028662

40 ft (12 m)

028663

45 ft (13.7 m)

028547

50 ft (15 m)

Advertising