APPENDIX F – SYSTEM GROUNDING

f-2

HySpeed HT2000

Instruction Manual

21

purchased locally, using a minimum 8 AWG UL Type MTW cable (USA specification) or the appropriate cable

specified by national and local codes.

Consult the appropriate manufacturer’s instructions to ground equipment that does not receive power from the

power supply.

Work Table Grounding

If a supplementary ground rod is installed near the worktable to reduce EMI, it must be connected directly to

the PE ground of the building structure, connected to the service ground; or to earth, providing the resistance

between the ground rod and the service ground meets national or local codes. Place the supplementary

ground rod within 20 ft (6 m) of the worktable according to national or local codes.

If any module is grounded to the work table, the work table must be grounded to the power supply, or the

configuration must be changed to comply with applicable national and local electrical codes.

A ferrite choke can be placed in the conductor between the work table ground rod and the PE ground, with a

number of turns through the choke to isolate the safety ground (at 60 Hz) from any electromagnetic

interference (frequencies above 150 Khz). The more turns the better. A suitable ferrite choke can be made by

wrapping 10 turns or more of the ground lead through Magnetics part number 77109-A7, Fair-Rite part

number 59-77011101, or other equivalent ferrite choke. Locate the choke as close as possible to the plasma

power supply.