POST-INSTALLATION

HySpeed HT2000

Instruction Manual

5-5

22

Adjust Preflow Gases

8. Set the

Test Preflow/Run/Test Cut Flow

toggle switch to

Test Preflow

.

Verify that the plasma gas pressure gauges on the gas console both read 120 psi (8.3 bar). 90 psi for

Air/N

2

process.

9. Look at the oxygen and/or nitrogen-air flowmeters and set the

Preflow

plasma gas flow rate % by

referring to the

Cut Charts

in

Section 6

and turning the oxygen and/or nitrogen-air

Preflow

adjust knobs.

10. Look at the shield gas pressure gauge on the gas console, and set to the

Cut Chart

specifications by

turning the shield gas adjust knob.

Adjust Cut Flow Gases and Check Initial Height Sensing (IHS)

11. Set the

Test Preflow/Run/Test Cut Flow

toggle switch to

Test Cut Flow

.

12. Look at the oxygen and/or nitrogen-air flowmeters and set the

Cut Flow

plasma gas flow rate % by

referring to the

Cut Charts

in

Section 6

. Use the

Cut Flow

toggle switch to set the plasma gases in this

mode. Verify that the O

2

plasma gas pressure reads 120 psi on the gas console. Adjust if necessary.

13. Set the switch to

Run

after setting the preflow and plasma flow rates.

14. Check the pilot arc operation by positioning the torch a

minimum of 3 inches (75mm)

above the work.

15. Depress the

START

button. After two seconds of gas preflow, the primary contactor will close and the

pilot arc will start. The pilot arc should emit a steady, hissing sound and a cone of light should appear at

the face of the torch nozzle. The pilot arc will continue for approximately 300 milli-seconds (O

2

), 600 milli-

seconds (Air/N

2

) and then go out automatically.

16. Place the metal on the work table to make a test pierce. With manual starting, no machine motion will

occur.

Note: The cutting machine must retract the torch at least one inch (25.4 mm) from the work

before the start cycle, or probes may hit the workpiece when START button is depressed.

Command THC users should reference the appropriate Command instruction manual.

17. Depress the

START

button. The probes will immediately descend and approximately 0.5 seconds later,

the torch will index toward the work. The

DOWN

indicator light on the V/C control should be on. When the

torch nears the work, probes will inductively detect work surface and down motion should stop. The

DOWN

indicator light on the V/C module will go off and the probes will start to retract.

At this point, depress the

STOP

button and disable the Initial Height Sensing. You are now ready for Final

Torch Adjustment.