Noise levels, Module grounding and grounding checks – Hypertherm HT2000-200 Volt User Manual

Page 56

Advertising
background image

INSTALLATION

HySpeed HT2000

Instruction Manual

4-3

24

Noise Levels

Figure 4-1 represents the noise levels in decibels experienced by an operator standing 10 feet from the torch

in a confined area under varied conditions while cutting 1-inch steel using oxygen/air at a travel speed of

20 ipm (508 mm/min).

Module Grounding and Grounding Checks

Please refer to

Grounding Requirements

in the

Pre-Installation

section of this manual for earth ground

specifications.

See Appendix F for system grounding requirements.

Before operating the system, perform the following grounding checks to ensure proper operation, personal

safety, and to reduce emission of radio-frequency interference:

• Ensure the power cord ground wire is properly connected to the ground in the line disconnect box.

• Ensure the power cord ground wire is properly connected to the power supply terminal

TB1

. Refer to

Connecting the Power

in the

Pre-Installation

section of this manual.

• Ensure that all electrical connections are tight to avoid excessive heating.

Figure 4-1

Noise Levels (Decibels)

Above water 6" without Water Muffler

106 dbs

Above water 6" with Water Muffler

104 dbs

Water at bottom of plate without Water Muffler

100 dbs

Water at bottom of plate with Water Muffler

95 dbs

Water 3" over plate without Water Muffler

75 dbs

Water 3" over plate with Water Muffler

72 dbs