Changing consumable parts – Hypertherm HT2000-200 Volt User Manual

Page 132

Advertising
background image

HySpeed HT2000

Instruction Manual

6-37

OPERATION

22

Changing Consumable Parts

Check the consumable parts daily for wear before cutting. Before removing parts, bring the torch to the edge

of the machine, with the lifter raised to its highest point. This prevents the danger of dropping the

consumables into the water of the water table.

Removal and Inspection –

Refer to Figure 6-7

1. Remove

Retaining cap

and

Shield

by unscrewing the retaining cap by hand.

2. Check the shield for external signs of wear. It should be clean and clear of metal debris. The gas holes

along the edge of the shield should not be blocked with debris. The center hole should not have any nicks

or gouges, and should show no signs of arcing activity.

3. Unscrew and remove the shield from the retaining cap. Inspect the gas holes from the inside. The holes

should be clear of metal or other debris. (Debris can cause arcing.)

4. Inspect the two O-rings on the

Torch body

. They should be lubricated and undamaged. If they are dry,

lubricate them lightly with a very thin film of the lubricant provided in the consumable parts kit. If they are

damaged, replace them.

5. Using the 3/4" side of the wrench supplied with the consumable parts kit, remove the

Nozzle

. Inspect it for

damage or signs of wear. You can clean the inside of the nozzle with steel wool, but be sure to remove

any remnants of the steel wool afterward. The hole in the nozzle should not be worn or oval-shaped.

6. Using the 3/8" center hole in the wrench, remove the

Electrode

and inspect it. If the center of an all copper

electrode has a pit more than .044" (1.1 mm) deep, replace it. A SilverPlus electrode should be replaced

when the pit depth exceeds approximately two times the recommended depth of an all copper electrode.

Use the electrode gauge assembly supplied in the consumable parts kit to measure pit depth. If the

electrode is still good, inspect its O-ring: it should be lubricated and undamaged. If it is dry, lubricate it

lightly with a very thin film of lubricant provided in the consumable parts kit. If it is damaged, replace it.

7. Remove the

Swirl ring

from the electrode and inspect it. It should be clean, and the holes on the top and

sides should not be plugged. Inspect its O-ring. It should be lubricated and undamaged. If it is dry,

lubricate it lightly with a very thin film of lubricant provided in the consumable parts kit. If it is damaged,

replace it.

8. Inspect the inside of the

Torch body

by using a mirror, or by looking carefully inside. The

Current ring

inside of the torch body should be clean and undamaged. Use a clean paper towel or Q-tip to remove dirt,

grease, etc. A preferred method to clean the current ring is with a clean paper towel or Q-tip dipped in

water or 3% hydrogen peroxide.

If the

Water tube

is damaged at all, it may need to be replaced. See

Changing the Water Tube

.

WARNING

Always disconnect power to the power supply before inspecting or changing torch consumable
parts.

Advertising