Aluminum, Above water only, 40 amps • air plasma / air shield – Hypertherm HT2000-200 Volt User Manual

Page 129

Advertising
background image

6-34

HySpeed HT2000

Instruction Manual

OPERATION

22

Shield

Arc

Approx.

Material

Plasma Gas Flow Rate %

Gas (Air)

Torch-to-work

Initial Torch

Voltage

Motion

Thickness

Preflow

Cutflow

Pressure

Distance

Piercing Height

Setting

Travel Speed

Delay Time

(inches)

(mm)

(Air %)

(Air %)

(psi)

(inches)

(mm)

(inches)

(mm)

(volts)

(ipm) (mm/min.)

(sec)

3/32

2.5

40

20

60

3/32

2.5

3/16

5

120

140

3550

1/8

3

(46.0

(23.1

(275

3/32

2.5

3/16

5

130

100

2550

0.5

1/4

6

SCFH)

SCFH)

SCFH)

1/8

3

140

35

900

3/8

10

1/8

3

150

15

350

Aluminum

40 amps • Air Plasma / Air Shield

This gas combination gives good cut speed, low dross levels and is very economical.

Notes:

Set plasma gas inlet pressure to 90 psi (6.2 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)

Production cutting above 1/8" (3 mm) not recommended

Above Water Only

020613

Swirl ring

120667

Electrode

020689

Nozzle

020423

Retaining cap

020688

Shield

Advertising