6-4

HySpeed HT2000

Instruction Manual

OPERATION

19

Front Panel Controls and Indicators (cont.)

Gas Console (Fig. 6-2)

• N

2

Air / O

2

Toggle Switch

(S1)

Selects the use of either nitrogen, air or oxygen as the plasma cutting gas.

• N

2

/ Air

Pressure Gauge

(PG1

)

Indicates the nitrogen or air plasma inlet pressure. Gas inlet pressures are specified in

Cut Charts

.

• N

2

/ Air

Flowmeter

(FM1)

Indicates the percentage rate of nitrogen or air plasma gas flow. Nitrogen or air flow rate % is specified in

Cut Charts

.

N

2

/ Air

Preflow

Metering Valve

(MV2)

Adjusts nitrogen or air plasma gas flow rate % while in

Test/Preflow

mode. Preflow plasma gas flow rate

percentages are specified in

Cut Charts

.

• O

2

Pressure Gauge

(PG2)

Indicates the oxygen plasma inlet pressure. Gas inlet pressures are specified in

Cut Charts

.

• O

2

Flowmeter

(FM2

)

Indicates the percentage rate of oxygen plasma gas flow. Oxygen flow rate % is specified in

Cut Charts

.

• O

2

Preflow

Metering Valve

(MV3)

Adjusts oxygen plasma gas flow rate % while in

Test/Preflow

mode. Preflow plasma gas flow rate

percentages are specified in

Cut Charts

.

• PLASMA Cut Flow

Switch

(S3)

Adjusts nitrogen, air or oxygen plasma gas flow rate % while in

Test Cut Flow

mode.

Cut Flow plasma gas flow rate percentages are specified in

Cut Charts

.

• Test Preflow/Run/Test Cut Flow

Toggle Switch

(S2)

Test Preflow

– This test position is used when setting the plasma preflow flow rate on the flowmeter. In this

position the contactor is disabled, so that current is not delivered to the electrode and the arc cannot be

fired.

Test Cut Flow –

This test position allows the selected plasma gas flow rate to be adjusted on the flowmeter

for cutting conditions. In this position also, the contactor is disabled so that current is not delivered to the

electrode and the arc cannot be fired.

Run –

This position enables the contactor and the subsequent firing of the arc after the gas rates have

been set in the

Test Preflow

and

Test Cut Flow

positions.