HySpeed HT2000

Instruction Manual

6-3

OPERATION

19

Figure 6-1

Power Supply Front Panel Controls and Indicators

INTERLOCK
TRANSFORMER
COOLANT LEVEL
SHIELD GAS/CAP
PLASMA GAS
COOLANT TEMP
COOLANT FLOW

ON (1)

OFF(0)

DC ON

STATUS Indicators Before Startup

When power is applied from the line disconnect switch and before the POWER ON (I) button is pushed, the

coolant flow LED will be illuminated. Once the POWER ON button is pushed and held for a few seconds, this

LED will extinguish if the system is in proper working condition.

Other fault conditions may also be indicated when the line power is switched on. Be sure to press and hold

the power supply POWER ON (I) button (in some cases up to 1 minute) to extinguish all status indicators. If

any LEDs remain illuminated, shut down the system and correct the problem. See