PRE-INSTALLATION

HySpeed HT2000

Instruction Manual

3-3

19

WARNING

Cutting with oxygen as the plasma gas can cause a potential fire hazard due to the oxygen-
enriched atmosphere that it creates. As a precaution, Hypertherm recommends that an exhaust
ventilation system be installed if you will be cutting with oxygen.

Oxygen, Nitrogen, or Argon-Hydrogen as Plasma Gas

From Source Supply to Gas Console

Refer to

Section 2

for gas specifications.

If

not

using hard plumbing to supply plasma gas to the gas console, we recommend using standard oxygen

hose with the system.

Note: If cutting with oxygen as the plasma gas, nitrogen must also be connected to the gas

console to achieve the proper oxygen/nitrogen mixtures in the preflow and cut flow

conditions.

From Gas Console to Motor Valve Console

Hose from the gas console to the motor valve console is provided by Hypertherm.

Shield Gas

From Source Supply to Gas Console

Refer to

Section 2

for gas specifications.

If

not

using hard plumbing, use 3/8-inch I.D. hose with the system. Hose can also be purchased through

Hypertherm.

From Gas Console to RHF Console

Hosing from the gas console to the RHF console is provided by Hypertherm.