Hypertherm HT2000-200 Volt User Manual

Page 168

Advertising
background image

MAINTENANCE

HySpeed HT2000

Instruction Manual

8-23

20

Relay Board LED Function List

D6: +12VDC

D11: SV4B

D16: SV1B

D22: Spare

D7: CR1

D12: SV4A

D17: SV2

D24: Machine Motion

D8: SV1A

D13: T1

D18: SV3

D26: Spare

D9: Ramp-down error

D14: Con1

D19: SV7

D28: SV6

D10: SV5

D15: LT1/LT2

D20: Output Enable

Rec 2

Rec 3

Rec 4

Rec 1

D6

D26

D24

D22 D28 D19 D13 D12 D11 D10 D9

D8

D7 D14 D15 D16 D17 D18

D20

Relay Board LED Status Conditions

(The following LEDs are illuminated during the conditions shown)

Idle

D6: +12VDC

D8: O

2

Solenoid Valve (SV1A), if in O

2

Mode

D16: N

2

Solenoid Valve (SV1B), if in N

2

Mode

D19: Cap Sense Solenoid Valve (SV7)

D20: Output Enable

D26: Spare

Test Preflow

D6: +12VDC

D8: O

2

Solenoid Valve (SV1A), if in O

2

Mode

D10: Plasma Off-Valve Solenoid Valve (SV5)

D11: Preflow Solenoid Valve (SV4B)

D19: Cap Sense Solenoid Valve (SV7)

D20: Output Enable

D26: Spare

D28: Shield Gas Solenoid Valve (SV6)